General specifications | |
---|---|
Switching function | Normally open (NO) |
Output type | PNP |
Rated operating distance | 2 mm |
Installation | flush |
Output polarity | DC |
Assured operating distance | 0 ... 1.62 mm |
Reduction factor rAl | 1 |
Reduction factor rCu | 1 |
Reduction factor r304 | 1 |
Reduction factor rSt37 | 1 |
Output type | 3-wire |
Nominal ratings | |
Operating voltage | 10 ... 30 V |
Switching frequency | 0 ... 4000 Hz |
Hysteresis | type 5 % |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | pulsing |
Voltage drop | ? 2.5 V |
Operating current | 0 ... 200 mA |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
No-load supply current | ? 15 mA |
Constant magnetic field | 200 mT |
Alternating magnetic field | 200 mT |
Switching state indicator | Multihole-LED, yellow |
Functional safety related parameters | |
MTTFd | 1010.5 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -45 ... 85 °C (-49 ... 185 °F) |
Mechanical specifications | |
Connection type | Connector M8 x 1 , 3-pin |
Housing material | Stainless steel 1.4305 / AISI 303 |
Sensing face | LCP , green |
Degree of protection | IP67 |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |