electrical ratings | |
---|---|
Voltage supply | 8...30 VDC |
Reverse polarity protection | Yes |
Short-circuit proof | Yes |
Consumption typ. | 35 mA (24 VDC, w/o load) |
Initializing time | ≤500 ms after power on |
Response time | < 1 ms |
Interface | Analog 0...10 Или отправьте нам запрос на / Resolution: 12 bit |
Function | Linear position feedback |
Linearity | ±0.65 % full scale output (f.s.o.) |
Absolute accuracy | ±0.65 % full scale output (f.s.o.)±1,13 % f.s.o. (+25 °C) ±1,41 % f.s.o. (-40...+85 °C) |
Sensing method | Magnetic |
Repeatability typ. | 5 mm |
Interference immunity | DIN EN 61000-6-2 |
Emitted interference | DIN EN 61000-6-4 |
Programmable parameters | Measuring range teachable |
Diagnostic function | Measuring range teachableSelf-diagnosis Reading back voltage output |
Factory setting | Entire measuring range Min. output at 0 m Max. output at 5 m |
mechanical design | |
Protection DIN EN 60529 | IP 65 (encoder) |
Material | IP 65 (encoder)Encoder housing: aluminium Cable-pull housing: PA6 GF30 Cable: Stainless steel cable coated with polyamide |
Operating temperature | -40...+85 °C |
Service life | Typ. >500000 strokes |
Measuring length | 5 m |
Cable acceleration | ≤50 m/s² |
Cable diameter | 0,61 mm |
Pull-in force | >3 N |
Pull-out force | ≤9 N |
Relative humidity | 95 % temporary condensing |
Resistance | 95 % temporary condensingDIN EN 60068-2-6 Vibration 10 g, 10-2000 Hz DIN EN 60068-2-27 Shock 50 g, 11 ms |
Weight approx. | 400 g |
Connection | 400 gFlange connector M12, 5-pin Flange connector M12, 8-pin Cable 2 m |
Bending radius | Cable: >55 mm |
Special characteristics | Coated electronic |
Instruction | Please consider the assembly instructions |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |